ML
    • Recent
    • Categories
    • Tags
    • Popular
    • Users
    • Groups
    • Register
    • Login

    Solved Troubleshooting poor network performance

    IT Discussion
    xen orchestra network performance backup aruba networking hub
    3
    10
    765
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • DustinB3403D
      DustinB3403
      last edited by DustinB3403

      Below is a screen capture of my NFS repos on Xen Orchestra, and the respective performance that I'm getting according to XO. I'm trying to sort out where my performance issues are stemming from and looking for some guidance.

      All remotes were just re-tested for consistency.
      c40ca362-92de-4460-ac5b-43a0a7c18b13-image.png

      After some digging around, I looked at my ESXi host (which is where XO is being run from - so its outside of the pool), and I noticed a 10MB Full Duplex NIC within ESXi.

      c40ddb18-03cb-4996-86ff-fe99fb76f049-image.png

      I've looked at the switch port (an Aruba 2530) and find Port 34 at 10FDx.

      da2a090c-b2df-422e-8220-159c3bc98b7b-image.png

      If I attempt to manually set the port speed to 1000 FD, I get "Value 1000-full is not applicable to port 34"

      If I check the network interface within XO, I get the below, which is not 10FDx...

      23a4c67e-ca91-480f-967a-dd995f72aa69-image.png

      A CLI Speed test shows
      c7973378-8b66-48cf-bf35-536c4be7e95d-image.png

      Would the next assumption be that this port is connected to a HUB and that physical re-cabling is going to be needed to address this?

      1 Reply Last reply Reply Quote 0
      • DustinB3403D
        DustinB3403 @DustinB3403
        last edited by

        @DustinB3403 said in Troubleshooting poor network performance:

        Moving from that port which was only giving 10FDx to an unused port, gave us 1000FDx.

        I'm not sure where this issue stems from..

        Got it sorted out, for some reason (and I'm still working on the specifics) our ESXi hosts secondary NIC keeps falling to 10FDx (likely some misconfiguration at setup).

        I've moved XO off of this nic, and performance has been fixed.

        scottalanmillerS 1 Reply Last reply Reply Quote 1
        • DustinB3403D
          DustinB3403
          last edited by

          In looking at the interface further, I do have quite a lot of dropped packets.

          93738b0b-0f1e-4e0b-bd61-42c44359b77e-image.png

          The switch has been up for 224d 16h 48m 21s

          DustinB3403D 1 Reply Last reply Reply Quote 0
          • DustinB3403D
            DustinB3403 @DustinB3403
            last edited by

            The Dropped Tx percentage is 0.6 of all packets dropped...

            jt1001001J 1 Reply Last reply Reply Quote 0
            • jt1001001J
              jt1001001 @DustinB3403
              last edited by

              @DustinB3403 I would think a hub would show half-duplex not full duplex?

              DustinB3403D scottalanmillerS 2 Replies Last reply Reply Quote 1
              • DustinB3403D
                DustinB3403 @jt1001001
                last edited by

                @jt1001001 I'm in office today, and moved the port from 34 to 33 and am now getting 1000FDx on the port and within ESXi.

                So it's very odd.

                1 Reply Last reply Reply Quote 0
                • DustinB3403D
                  DustinB3403
                  last edited by

                  Moving from that port which was only giving 10FDx to an unused port, gave us 1000FDx.

                  I'm not sure where this issue stems from..

                  DustinB3403D 1 Reply Last reply Reply Quote 0
                  • DustinB3403D
                    DustinB3403 @DustinB3403
                    last edited by

                    @DustinB3403 said in Troubleshooting poor network performance:

                    Moving from that port which was only giving 10FDx to an unused port, gave us 1000FDx.

                    I'm not sure where this issue stems from..

                    Got it sorted out, for some reason (and I'm still working on the specifics) our ESXi hosts secondary NIC keeps falling to 10FDx (likely some misconfiguration at setup).

                    I've moved XO off of this nic, and performance has been fixed.

                    scottalanmillerS 1 Reply Last reply Reply Quote 1
                    • DustinB3403D DustinB3403 has marked this topic as solved on
                    • scottalanmillerS
                      scottalanmiller @jt1001001
                      last edited by

                      @jt1001001 said in Troubleshooting poor network performance:

                      @DustinB3403 I would think a hub would show half-duplex not full duplex?

                      It would definitely. A hub cannot be FDX.

                      1 Reply Last reply Reply Quote 0
                      • scottalanmillerS
                        scottalanmiller @DustinB3403
                        last edited by

                        @DustinB3403 said in Troubleshooting poor network performance:

                        @DustinB3403 said in Troubleshooting poor network performance:

                        Moving from that port which was only giving 10FDx to an unused port, gave us 1000FDx.

                        I'm not sure where this issue stems from..

                        Got it sorted out, for some reason (and I'm still working on the specifics) our ESXi hosts secondary NIC keeps falling to 10FDx (likely some misconfiguration at setup).

                        I've moved XO off of this nic, and performance has been fixed.

                        If you want to improve ESXi performance, install KVM.

                        DustinB3403D 1 Reply Last reply Reply Quote 1
                        • DustinB3403D
                          DustinB3403 @scottalanmiller
                          last edited by

                          @scottalanmiller said in Troubleshooting poor network performance:

                          @DustinB3403 said in Troubleshooting poor network performance:

                          @DustinB3403 said in Troubleshooting poor network performance:

                          Moving from that port which was only giving 10FDx to an unused port, gave us 1000FDx.

                          I'm not sure where this issue stems from..

                          Got it sorted out, for some reason (and I'm still working on the specifics) our ESXi hosts secondary NIC keeps falling to 10FDx (likely some misconfiguration at setup).

                          I've moved XO off of this nic, and performance has been fixed.

                          If you want to improve ESXi performance, install KVM.

                          Yea, that's a different conversation entirely, I do want a outside of the XCP-ng pool environment, in case something goes sideways. I'm dealing with some sunkcost conversations about it, though I am making progress.

                          1 Reply Last reply Reply Quote 2
                          • 1 / 1
                          • First post
                            Last post