    Estación de trabajo con 10 segundos de atraso en el reloj

    IT Discussion
    windows time synchronization active directory ntp sntp
    5
    15
    1.1k
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • scottalanmillerS
      scottalanmiller
      last edited by

      @Suyeins said in Estación de trabajo con 10 segundos de atraso en el reloj:

      Solo me dice que ocurrió un error.

      Creo que veo el problema. La estación de trabajo se está sincronizando con una fuente de tiempo del gobierno en lugar de Active Directory. ¿Pero no es esto una máquina de memoria de Active Directory?


      I think that I see the issue. The workstation is synchronizing with a government time source instead of Active Directory. But isn't this an Active Directory memory machine?

      SuyeinsS 1 Reply Last reply Reply Quote 0
      • SuyeinsS
        Suyeins @scottalanmiller
        last edited by

        @scottalanmiller No estoy segura.
        Por otro lado empecé a comparar con otras maquinas del mismo lugar y en casi todas las maquinas hay atrasos de 3 a 6 segundos. No es un problema de solo una maquina.

        1 Reply Last reply Reply Quote 0
        • scottalanmillerS
          scottalanmiller
          last edited by

          @Suyeins said in Estación de trabajo con 10 segundos de atraso en el reloj:

          @scottalanmiller No estoy segura.
          Por otro lado empecé a comparar con otras maquinas del mismo lugar y en casi todas las maquinas hay atrasos de 3 a 6 segundos. No es un problema de solo una maquina.

          De tres a seis segundos es muy pequeño. Anticipamos una pequeña variación entre las máquinas de Windows. Acabo de mirar y no hay Active Directory aquí. Así que todas las máquinas deben ir a la fuente del gobierno.

          1 Reply Last reply Reply Quote 0
          • RomoR
            Romo
            last edited by Romo

            No AD, its work group computers. There is a manual Local Policy set that removes admin users from being able to change the time as all users have admin accounts for Avimark.

            scottalanmillerS 1 Reply Last reply Reply Quote 1
            • dbeatoD
              dbeato
              last edited by

              Pero solo son 10 segundos atrasado, cual es el inconveniente?

              1 Reply Last reply Reply Quote 0
              • scottalanmillerS
                scottalanmiller @Romo
                last edited by

                @Romo said in Estación de trabajo con 10 segundos de atraso en el reloj:

                No AD, its work group computers. There is a manual Local Policy set that removes admin users from being able to change the time as all users have admin accounts for Avimark.

                We should make a script to get the time variance across the whole site.

                1 Reply Last reply Reply Quote 0
                • scottalanmillerS
                  scottalanmiller
                  last edited by

                  Anyone know what the normal variance on Windows boxes is when not using a local time source? How close in seconds would we even expect a site to be able to be?

                  dbeatoD 1 Reply Last reply Reply Quote 0
                  • scottalanmillerS
                    scottalanmiller
                    last edited by

                    Windows time only syncs weekly, normally. So off by several seconds is part of the expectation of Windows time service.

                    dafyreD 1 Reply Last reply Reply Quote 0
                    • dafyreD
                      dafyre @scottalanmiller
                      last edited by

                      @scottalanmiller said in Estación de trabajo con 10 segundos de atraso en el reloj:

                      Windows time only syncs weekly, normally. So off by several seconds is part of the expectation of Windows time service.

                      I've seen places use Windows Tasks to sync the time to external time sources if it needs to be more often than weekly.

                      1 Reply Last reply Reply Quote 0
                      • dbeatoD
                        dbeato @scottalanmiller
                        last edited by

                        @scottalanmiller said in Estación de trabajo con 10 segundos de atraso en el reloj:

                        Anyone know what the normal variance on Windows boxes is when not using a local time source? How close in seconds would we even expect a site to be able to be?

                        You can have it up to 5 minutes from the Domain Controller Servers time.

                        scottalanmillerS 1 Reply Last reply Reply Quote 0
                        • scottalanmillerS
                          scottalanmiller @dbeato
                          last edited by

                          @dbeato said in Estación de trabajo con 10 segundos de atraso en el reloj:

                          @scottalanmiller said in Estación de trabajo con 10 segundos de atraso en el reloj:

                          Anyone know what the normal variance on Windows boxes is when not using a local time source? How close in seconds would we even expect a site to be able to be?

                          You can have it up to 5 minutes from the Domain Controller Servers time.

                          No DCs. No AD.

                          dbeatoD 1 Reply Last reply Reply Quote 0
                          • dbeatoD
                            dbeato @scottalanmiller
                            last edited by

                            @scottalanmiller said in Estación de trabajo con 10 segundos de atraso en el reloj:

                            @dbeato said in Estación de trabajo con 10 segundos de atraso en el reloj:

                            @scottalanmiller said in Estación de trabajo con 10 segundos de atraso en el reloj:

                            Anyone know what the normal variance on Windows boxes is when not using a local time source? How close in seconds would we even expect a site to be able to be?

                            You can have it up to 5 minutes from the Domain Controller Servers time.

                            No DCs. No AD.

                            Gotcha, I am still trying to see what is the issue. 10 seconds is almost unnoticeable. What is the purpose?

                            1 Reply Last reply Reply Quote 0