    Looking for some UBNT help

    IT Discussion
    ubnt us-8 switch
    3
    11
    1.0k
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • KellyK
      Kelly
      last edited by

      So I just put a US-8 in at a customer site, and it is behaving oddly. It will basically shut its ports off for extended periods of time, and then come back on a few hours later. The switch appears to be on still since the power light is on, but the port LEDs are off and there is no traffic flowing. I have an ERL, a Netgear WAP, a printer, and 3 computers (two clients and a backup server) connected to it. Nothing is plugged into the single PoE port (eth0/7). Any thoughts?

      JaredBuschJ 1 Reply Last reply Reply Quote 0
      • JaredBuschJ
        JaredBusch @Kelly
        last edited by

        @kelly said in Looking for some UBNT help:

        So I just put a US-8 in at a customer site, and it is behaving oddly. It will basically shut its ports off for extended periods of time, and then come back on a few hours later. The switch appears to be on still since the power light is on, but the port LEDs are off and there is no traffic flowing. I have an ERL, a Netgear WAP, a printer, and 3 computers (two clients and a backup server) connected to it. Nothing is plugged into the single PoE port (eth0/7). Any thoughts?

        Bad power is the first thing that comes to mind.

        KellyK 1 Reply Last reply Reply Quote 1
        • JaredBuschJ
          JaredBusch
          last edited by

          Is the firmware current?

          Do you have UNMS? If so, does that show it going offline too?

          KellyK 1 Reply Last reply Reply Quote 1
          • JaredBuschJ
            JaredBusch
            last edited by

            Wait US? UniFi Switch? Is it dropping from the controller?

            KellyK 1 Reply Last reply Reply Quote 0
            • KellyK
              Kelly @JaredBusch
              last edited by

              @jaredbusch said in Looking for some UBNT help:

              Wait US? UniFi Switch? Is it dropping from the controller?

              Yes, since the controller is plugged into it.

              1 Reply Last reply Reply Quote 0
              • KellyK
                Kelly @JaredBusch
                last edited by

                @jaredbusch said in Looking for some UBNT help:

                Is the firmware current?

                Do you have UNMS? If so, does that show it going offline too?

                Current firmware. I don't have the number is front of me, but it is 3.9.x.

                1 Reply Last reply Reply Quote 0
                • KellyK
                  Kelly @JaredBusch
                  last edited by

                  @jaredbusch said in Looking for some UBNT help:

                  @kelly said in Looking for some UBNT help:

                  So I just put a US-8 in at a customer site, and it is behaving oddly. It will basically shut its ports off for extended periods of time, and then come back on a few hours later. The switch appears to be on still since the power light is on, but the port LEDs are off and there is no traffic flowing. I have an ERL, a Netgear WAP, a printer, and 3 computers (two clients and a backup server) connected to it. Nothing is plugged into the single PoE port (eth0/7). Any thoughts?

                  Bad power is the first thing that comes to mind.

                  It is just in a power strip, but I'll try a different outlet.

                  1 Reply Last reply Reply Quote 0
                  • DustinB3403D
                    DustinB3403
                    last edited by

                    You're using a physical controller and not a virtual one?

                    KellyK 1 Reply Last reply Reply Quote 0
                    • JaredBuschJ
                      JaredBusch
                      last edited by

                      RMA will take time. buy a new one immediately and then RMA this one.

                      Then you will have a spare to use elsewhere or keep on the shelf. or resell.

                      1 Reply Last reply Reply Quote 3
                      • KellyK
                        Kelly @DustinB3403
                        last edited by

                        @dustinb3403 said in Looking for some UBNT help:

                        You're using a physical controller and not a virtual one?

                        The controller software is running on one of the desktops.

                        1 Reply Last reply Reply Quote 0
                        • KellyK
                          Kelly
                          last edited by

                          It turns out that the outlet that I had the switched plugged into via a powerstrip had one always on outlet and the other was switched. So whenever they would leave they would turn off the lamp connected to the switched outlet...and their network switch. Good times. I moved some things around and the switch is now on a UPS and off that switched outlet.

                          1 Reply Last reply Reply Quote 5